ESPAÑOL
The 1-2 pair pins are shorted
together and the 7-8 pair is
open. The pins with the errors
are flashing. Dash lines (-) on
the bottom (remote) display
line indicate the short, while
line indicate the open pair.
T568A Cable with a miswire and
are connected to pins 2 and 1 at
the remote-end. The pins with this
error are flashing. The “U” for the
remote pin numbers indicates an
unrecognizable continuity was
detected that is neither a short
WIRING AND DISPLAY EXAMPLES
T568A Cable with a Short and Open:
T568A Cable with a Miswire and
single screw in the middle of the back of the
with a #0 Phillips head screwdriver. Remove battery door.
exhausted batteries. Hitting the palm of your cupped
hand with the back of the
will usually dislodge the
batteries from the compartment.
4 x 1.5 alkaline batteries (IEC LR44, ANSI/NEDA 1166A).
batteries into battery compartment with the battery plus sign
(+) in the direction of the plus sign on the case (the spring contact is
negative and the button contact is positive). Inserting the last battery
in the middle of the stack is the easiest.
battery door and screw, taking care not to over-tighten it.
ENGLISH
www.kleintools.com/warranty
Turn instrument off and disconnect any cables. Clean the instrument by
using a damp cloth. Do not use abrasive cleaners or solvents.
Remove the batteries when instrument is not in use for a prolonged
period of time. Do not expose to high temperatures or humidity. After a
period of storage in extreme conditions exceeding the limits mentioned
in the Specifications section, allow the instrument to return to normal
operating conditions before using it.
Do not place equipment and its accessories in
the trash. Items must be properly disposed of in
accordance with local regulations.
Prior to disposal of this product, please contact
Klein Tools for proper disposal options.