CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
139560T Rev. 11/13 B
ENGLISH
AUTO / MANUAL
RANGE
• DATA HOLD
• 3-1/2 DIGIT
1999 COUNT LCD
• BACKLIGHT
• WORKLIGHT
• TEMPERATURE
ENGLISH
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range Resolution Accuracy
400mV 0.1mV
± (0.8% + 2 digits)
4V 0.001V
40V 0.01V
400V 0.1V
600V 1V ± (1.0% + 2 digits)
Overload Protection: 600V DC / AC
Input Impedance: 10MΩ.
AC Voltage Measurement
Range Resolution Accuracy
400mV 0.1mV
± (1.0% + 10 digits)
4V 0.001V
40V 0.01V
400V 0.1V
600V 1V ± (1.2% + 10 digits)
Overload Protection: 600V DC / AC
Frequency: 40 to 400Hz
Input Impedance: 10MΩ.
Response: Averaging
AC Current Measurement
Range Resolution Accuracy
4A 0.001A ± (3.5% + 20 digits)
0.5A
4A 0.001A ± (3.0% + 10 digits)
>
0.5A
40A 0.01A ± (3.0% + 10 digits)
400A 0.1A ± (2.5% + 10 digits)
600A 1A ± (1.5% + 5 digits)
Overload Protection: 720A for 60 sec. max
Frequency: 50 to 60Hz
Response: Averaging
Resistance Measurement
Range Resolution Accuracy
400Ω 0.1Ω
± (1.2% + 2 digits)
4kΩ 0.001kΩ
40kΩ 0.01kΩ
400kΩ 0.1kΩ
4MΩ 0.001MΩ
40MΩ 0.01MΩ
± (2.0% + 5 digits)
Overload Protection: 600V DC / AC
Capacitance Measurement
Range Resolution Accuracy
50nF 0.01nF ± (3.0% + 10 digits)
500nF 0.1nF
± (3.0% + 5 digits)
5µF 0.001µF
50µF 0.01µF
100µF 0.1µF
Overload Protection: 600V DC / AC
Frequency Measurement
Range Resolution Accuracy
50Hz 0.01Hz
± (0.1% + 3 digits)
500Hz 0.1Hz
5kHz 0.001kHz
50kHz 0.01kHz
100kHz 0.1kHz
Overload Protection: 600V DC / AC
Duty Cycle Measurement
Range Resolution Accuracy
0.1
˜
99.9% 0.1% ± (3.0% + 0 digits)
Overload Protection: 600V DC / AC
Temperature Measurement
Range Resolution Accuracy
-4
˜
1832°F 1°F ± (3.0% + 3 digits)
-20
˜
1000°C 1°C ± (3.0% + 2 digits)
Overload Protection: 600V DC / AC
Diode Test
Overload Protection Resolution Open Circuit Voltage
600V DC / AC 1mV Appx. 1.5V
Continuity Test
Overload Protection Resolution Open Circuit Voltage
600V DC / AC
100mΩ
Appx. 0.45V
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
Dwg Name: CL200-139560TART Dwg No: 139560T
ECO No: 15429 Pkg Dwg Ref: 1650 Rev: B
Color Reference: N/A
Instruction Manual
CL200
600A
600V
CL200 Instruction Manuals - MASTER.indd 1-4 12/16/2013 12:16:18 PM
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - Instruction Manual

CUSTOMER SERVICEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 600691-877-775-5346customerservice@kleintools.comwww.kleintools.com139560T Rev. 11/13

Page 2

ENGLISH1BC3FAEDGHHA. Use CAT III rated leads or higher.Do not attempt to measure more than 600V or any current on lead input.B. Keep hands below lin

Page 3 - Manual de

SERVICIO AL CLIENTEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 600691-877-775-5346customerservice@kleintools.comwww.kleintools.com139561T Rev. 11

Page 4 - Manual de instrucciones

ESPAÑOL1BC3FAEDGHHA. Utilice cables con clasi cación CAT III o superior. No intente medir más de 600V o una corriente del valor que sea en la entra

Page 5 - Manuel d’utilisation

139562T Rev. 11/13 BSERVICE À LA CLIENTÈLEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL [email protected]

Page 6

FRANÇAIS1BC3FAEDGHHA. Utilisez des  ls conformes à la norme CATIII ou supérieure.Ne tentez pas de mesurer des valeurs supérieures à 600V ou tout c

Commentaires sur ces manuels

Pas de commentaire